HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink Home Downloads Links About Contacts

Motor/Armature Winders

Postma & Postma rewind AC & DC motors, armatures and synchronous motors for the industry.

 

Electric motors are dismantled, bearing areas on the rotor or end plates are checked, compared to standards and repaired in house if necessary.  See - Machining

 

Couplings, pulleys and bearings are removed with hydraulic pullers.

 

A growler test or MCA, is performed on squirrel cage motor rotors to ensure the rotor bars are intact. Core loss testing is performed on the stator and rotor cores to ensure the motor is still viable to repair.

 

New bearings are fitted by means of induction heating.

 

We rewind the stator and take the utmost care to ensure we rewind to original specifications. Motor Circiut Analysis is performed on the stator windings before they are varnished and cured. See - Motor Circuit Analysis

 

Electric motors above 180 frame are double varnished and cured in an oven with regulated temperature control.

 

We dynamically balance the rotors, armatures and couplings. See Dynamic Balancing

 

The motors are assembled and test run under no load conditions. No load currents are checked and compared to standards. A frequency analysis, of the motors, is done on our test bed. See - Vibration Analysis

HyperLink HyperLink HyperLink HyperLink HyperLink HyperLink

POSTMA & POSTMA

(PTY) LTD.